Be sure to read and follow the “General Safety Information
and Caution” before doing any work related with the high voltage
system. Failure to follow the safety instructions may result in serious
electrical injuries.
•
Be sure to shut off the high voltage before doing any work
related with the high voltage system(Refer to "High Voltage Shut-off
Procedure"). Failure to follow the safety instructions may result in
serious electrical injuries.
When removing the battery pack assembly to inspect the
battery system, it can be connected to vehicle by using the SST
0K918-E4100, 0K375-E4100, 0K375-E4200. Before installing the battery
system assembly, check if the battery is OK by using the SST.
Pre Charge Relay Inspection
[Using multi tester (Relay OFF)]
Inspect the high voltage pre-charge relay by using multi tester when the relay is off
1.
Shut off the high voltage.
(Refer to Battery Control System - "High Voltage Shut-off Procedure")
2.
Remove the high voltage battery upper case.
(Refer to High Voltage Battery System - "Case")
3.
Measure the resistance between the high voltage (+) power terminal and the joint box (+) terminal.
Specification : ??(20°C)
[Using GDS (Relay ON)]
1.
Shut off the high voltage.
(Refer to Battery Control System - "High Voltage Shut-off Procedure")
2.
Remove the high voltage battery upper case.
(Refer to High Voltage Battery System - "Case")
3.
Connect the SST(0K918-E4100, 0K375-E4100, 0K375-E4200) to the vehicle.
4.
Connect the GDS to DLC.
5.
Turn the ignition swtich ON.
6.
Activate the pre charge relay by using "Actuation Test" on the GDS as shown in the illustration below.
When the relay is ON, there is a relay operation sound.
Pre Charge Relay Coil Resistance
1.
Shut off the high voltage.
(Refer to Battery Control System - "High Voltage Shut-off Procedure")
2.
Remove the power relay assembly (PRA)
(Refer to High Voltage Battery System - "Power Relay Assembly (PRA)")
3.
Measure the resistance between pins No. 6 and No. 8 of the power relay assembly connector.
Specification : 104.4 ~ 127.6 ? (20°C)
Removal
Main Relay, Pre Charge Relay, Pre Charge Resistor, Battery
Current Sensor, High Voltage Battery Heater Relay and the High Voltage
Battery Heater Fuse are integrated in the Power Relay Assembly (PRA). So
Refer to the removal procedure of Power Relay Assembly (PRA).
Installation
Main Relay, Pre Charge Relay, Pre Charge Resistor, Battery
Current Sensor, High Voltage Battery Heater Relay and the High Voltage
Battery Heater Fuse are integrated in the Power Relay Assembly (PRA). So
Refer to the installation procedure of Power Relay Assembly (PRA).
System Circuit Diagram
With High Voltage Battery Heater System
Without High Voltage Battery Heater System
Circuit Diagram
Without High Voltage Battery Heater System
With High Voltage Batt ...
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front/rear bumper cover.
(Refer to Body - "Front Bumper Cover")
(Refer to Body - "Rear Bumper Cover")
3.
Disconnect the connector (A) from the ultrasonic sensor.
[Front sensor, Rear center sensor]