Description
Pre-Charge Resistor is installed in the Power Relay Assembly
(PRA) and it protects the high voltage circuit by limiting the charging
current when the inverter capacitor is being pre ...
Removal
Main Relay, Pre Charge Relay, Pre Charge Resistor, Battery
Current Sensor, High Voltage Battery Heater Relay and the High Voltage
Battery Heater Fuse are in ...
Description
Electric compressors improve the fuel efficiency and operates the air conditioner even when the engine has stopped.
Operation Principle
Compression Part
One of the scrolls is fixed while the other orbits
eccentrically without self-rotating, thereby to trap and pump
refrigeran ...
Warning Lamp Activation
Warning Lamp Behavior after Ignition On
As soon as the operating voltage is applied to the SRSCM ignition input, the SRSCM activates the warning lamp for a lamp check.