Kia Soul EV: High Voltage Battery Control System / Pre-charge Relay Specifications

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Battery Control System / Pre-charge Relay Specifications

Specification
Item
Specification
ON
Rated Voltage(V)
450
Rated Ampere(A)
10
Voltage Drop(V)
Less than 0.5 (10A)
Coil
Operation Voltage(V)
12
Resistance(?)
104.4 ~ 127.6 (20°C)

Item
Specification
Remark
Main Relay Switch (-) Resistance (?)
?
Checkable by multi tester
Pre Charger Relay Operation Sound
"Clicking"
Checkable by GDS and SST
Pre Charger Relay Coil Resistance (?)
104.4 ~ 127.6 (20°C)
Checkable by multi tester

Main Relay Repair procedures
Inspection     • Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failur ...

Pre-charge Relay Description and Operation
Description Installed in the Power Relay Assembly (PRA), the Pre-charge Relay connects high voltage circuit when pre-charging the inverter capacitor. When the IG is ON, the current coming thro ...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: Relay Box (Engine Compartment) Components and Components Location


Component Location ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: High Voltage Battery Heater Description and Operation


Description High Voltage Battery Heater is installed in every module and it is controlled by heater relay. High Voltage Flow Control FlowOperation ...