Kia Soul EV: High Voltage Battery Control System / Pre-charge Relay Specifications
Item
| Specification
|
ON
| Rated Voltage(V)
| 450
|
Rated Ampere(A)
| 10
|
Voltage Drop(V)
| Less than 0.5 (10A)
|
Coil
| Operation Voltage(V)
| 12
|
Resistance(?)
| 104.4 ~ 127.6 (20°C)
|
Item
| Specification
| Remark
|
Main Relay Switch (-) Resistance (?)
| ?
| Checkable by multi tester
|
Pre Charger Relay Operation Sound
| "Clicking"
| Checkable by GDS and SST
|
Pre Charger Relay Coil Resistance (?)
| 104.4 ~ 127.6 (20°C)
| Checkable by multi tester
|
Inspection
•
Be sure to read and follow the “General Safety Information
and Caution” before doing any work related with the high voltage
system. Failur ...
Description
Installed in the Power Relay Assembly (PRA), the Pre-charge
Relay connects high voltage circuit when pre-charging the inverter
capacitor.
When the IG is ON, the current coming thro ...
Other information:
Description
1.
The ESP OFF switch is used by users to turn off the ESP system.
2.
The ESP OFF lamp is on when ESP OFF switch is engaged.
...
Component Location
1. Rear transverse trim
...