Kia Soul EV: Heating,Ventilation, Air Conditioning / Specifications
Air Conditioner
Item
| Specification
|
Compressor
| Type
| ESC33n (Electric Scroll)
|
Communication type
| CAN communication
|
Oil type & Capacity
| POE OIL, 180±10g
|
Motor type
| BLDC
|
Rated voltage
| 360V
|
Operation voltage
| 240~413V
|
Displacement
| 33cc/rev
|
Condensor
| Heat rejection
| 13,400 -3% kcal/hr
|
Air pressure transducer
| Pressure value
| Voltage=0.00878835*Pressure(psig)+0.5
|
Expansion valve
| Type
| Block type
|
Refrigerant
| Type
| R-134a
|
Capacity
| Without heat pump
| 550±25g (19.4±0.88 oz.)
|
With heat pump
| 900±25g (31.7±0.88 oz.)
|
Heater And Evaporator Unit
Item
| Specification
|
PTC Heater
| Type
| Fin & Tube type
|
Operating voltage
| DC 240V ~ 420V
|
Heating capacity
| 4,700 ± 5% kcal/hr
|
Heat Pump
| Exterior Condensor
| Heating capacity
| 17,000 - 3% kcal/hr
|
Interior Condensor
| 2,600 - 5% kcal/hr
|
Chiller
| 770g
|
Accumulator
| 950cc
|
Mode operating type
| Actuator
|
Evaporator
| Temperature operating type
| Actuator
|
Temperature contorl type
| Evaporator temperature sensor
|
A/C ON/OFF
| ON : 2.3±0.5°C, OFF : 0.6±0.5°C
|
Heating capacity
| 4,700 - 5% kcal/hr
|
High Voltage Shut-off Procedure
Be sure to read and follow the “General Safety Information
and Caution” before doing any work related with the high voltage
syst ...
Special Service Tools
Personal Protective Equipment
NameIllustrationDescriptionInsulation glovesUsed when inspecting or working on the high voltage components[Insulation performance : 1000V / ...
Other information:
Component Location
1. Heater unit
Components
[LH]
1. Floor shower duct assembly [LH]2. Duct sensor3. Interior condenser cover4. Heater core cover5. Temp door arm6. Temp door lever7. Temp actuator motor assembly8. Floor door lever9. Mode actuator motor assembly [LH]10. Mode cam11. Motor ...
Component Location
[Without Heat Pump]
1. Refrigerant line
[With Heat Pump]
1. Refrigerant line
...