Kia Soul EV: Heating,Ventilation, Air Conditioning / Specifications
Air Conditioner
Item
| Specification
|
Compressor
| Type
| ESC33n (Electric Scroll)
|
Communication type
| CAN communication
|
Oil type & Capacity
| POE OIL, 180±10g
|
Motor type
| BLDC
|
Rated voltage
| 360V
|
Operation voltage
| 240~413V
|
Displacement
| 33cc/rev
|
Condensor
| Heat rejection
| 13,400 -3% kcal/hr
|
Air pressure transducer
| Pressure value
| Voltage=0.00878835*Pressure(psig)+0.5
|
Expansion valve
| Type
| Block type
|
Refrigerant
| Type
| R-134a
|
Capacity
| Without heat pump
| 550±25g (19.4±0.88 oz.)
|
With heat pump
| 900±25g (31.7±0.88 oz.)
|
Heater And Evaporator Unit
Item
| Specification
|
PTC Heater
| Type
| Fin & Tube type
|
Operating voltage
| DC 240V ~ 420V
|
Heating capacity
| 4,700 ± 5% kcal/hr
|
Heat Pump
| Exterior Condensor
| Heating capacity
| 17,000 - 3% kcal/hr
|
Interior Condensor
| 2,600 - 5% kcal/hr
|
Chiller
| 770g
|
Accumulator
| 950cc
|
Mode operating type
| Actuator
|
Evaporator
| Temperature operating type
| Actuator
|
Temperature contorl type
| Evaporator temperature sensor
|
A/C ON/OFF
| ON : 2.3±0.5°C, OFF : 0.6±0.5°C
|
Heating capacity
| 4,700 - 5% kcal/hr
|
High Voltage Shut-off Procedure
Be sure to read and follow the “General Safety Information
and Caution” before doing any work related with the high voltage
syst ...
Special Service Tools
Personal Protective Equipment
NameIllustrationDescriptionInsulation glovesUsed when inspecting or working on the high voltage components[Insulation performance : 1000V / ...
Other information:
Component Location
1. Rear seat belt retractor
...
Replacement
•
Put on gloves to protect your hands.
•
When prying with a flat-tip screwdriver, wrap it with
protective tape, and apply protective tape around the related parts, to
prevent damage.
•
Ta ...