Specification
High Voltage Shut-off Procedures
? Specification
ItemSpecificationRemarkCapacitor Voltage between the inverter terminalsLess than 30VCheckable by multi tester
High Voltage Ba ...
Description and Operation
Electric vehicle is powered by transforming electric energy
into kinetic energy in the motor and high voltage battery. It can be
recharged by high voltage energy via I ...
Installation
Battery temperature sensor can not be disassembled.
1.
Turn the ignition switch OFF.
2.
Shut off the high voltage.
(Refer to Battery Control System - "High Voltage Shut-off Procedure")
3.
Remove the high voltage battery system assembly.