Description
Power relay assembly (PRA) is installed in the high voltage
battery system assembly and it consists of main relays which control the
high voltage, pre-charge relay, pre-charge resister and battery current
sensor. PRA controls high voltage of 360V between the high voltage
batte ...
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the negative (-) battery terminal.
3.
Verify that the auto defogging actuator operates to the open
position when 12V is connected to terminal 3 and ground to terminal 4.
Verify that the auto defogging actuator operates to the c ...