Wrap tin foil around the end of the voltmeter test lead to
prevent damaging the heater line. Apply finger pressure on the tin foil,
moving the tin foil along the grid line to check for open circuits.
1.
Turn on the defogger switch and use a voltmeter to measure
the voltage of each heater line at the glass center point. If a voltage
of approximately 6V is indicated by the voltmeter, the heater line of
the rear window is considered satisfactory.
2.
If a heater line is burned out between the center point and (+) terminal, the voltmeter will indicate 12V.
3.
If a heater line is burned out between the center point and (-) terminal, the voltmeter will indicate 0V.
4.
To check for open circuits, slowly move the test lead in the
direction that the open circuit seems to exist. Try to find a point
where a voltage is generated or changes to 0V. The point where the
voltage has changed is the open-circuit point.
5.
Use an ohmmeter to measure the resistance of each heater line
between a terminal and the center of a grid line, and between the same
terminal and the center of one adjacent heater line. The section with a
broken heater line will have a resistance twice that in other sections.
In the affected section, move the test lead to a position where the
resistance sharply changes.
Repairing Broken Heater Line
Prepare the following items :
1.
Conductive paint.
2.
Paint thinner.
3.
Masking tape.
4.
Silicone remover.
5.
Using a thin brush :
Wipe the glass adjacent to the broken heater line, clean with
silicone remover and attach the masking tape as shown. Shake the
conductive paint container well, and apply three coats with a brush at
intervals of about 15 minutes apart. Remove the tape and allow
sufficient time for drying before applying power. For a better finish,
scrape away excess deposits with a knife after the paint has completely
dried. (Allow 24 hours).
Inspection
1.
The windshield deicer switch inputs can be checked using the GDS.
2.
To check the input value of windshield deicer switch, select "Body Control Module" menu.
3.
Select "Curre ...
Inspection
1.
Measure the pressure of high pressure line by measuring voltage output between terminals No. 1 and No. 2.
2.
Inspect the voltage value whether it is within the specified range.
Voltage = 0.00878835 * Pressure + 0.5[PSIA]
3.
If the measured voltage value is not within t ...